FTP 23AWG Ethernet CAT 6A Cable Solid Bare Copper PVC Jacket

Brand Name : TC

Model Number : FTP-11-6A-4P-V1

Certification : UL, RoSH, REACH, CE

Place of Origin : China

MOQ : 50 Boxes

Price : Negotiable

Payment Terms : Western Union, T/T, L/C, MoneyGram

Packaging Details : Seaworthy Packing

Type : Cat 6A F/UTP

Conductor Material : 99.99% BC

Conductor OD : 23 AWG

Jacket Material : PVC

Drain Wire : Yes

Cross Spline : PE

Insulation : HDPE

Rip Cord : Yes

Contact Now

Cat 6A Cable, CAT6A Network Cable, FTP CAT6A Cable, CAT 6A Ethernet Cable Application


It can be applied in horizontal cabling, as the portion of a telecommunications cabling system that extends from the work area telecommunications outlet to the patch panels in the distribution room, and in residential cabling that extends from the user telecommunications outlet to the patch panels.

Product Features


TC's Cat 6A, 23 AWG, 4-pair, U/FTP shielded indoor cable adopts cross-type spline and overall aluminum foil shield, optimized to greatly enhance technical indicators, including Attenuation, NEXT, and ANEXT, which exceed the parameters specified in GB/T 18015.5 (IEC 61156-5) standards.

It is especially useful in some harsh electromagnetic environments where high-speed and stable cable transmission is required.

At the same time, it acts on the requirements for high transmission in data center, and structured structured cabling in new buildings.

Application Standards


TIA/EIA568-C.2

Technical Details

Transmission Performance Cat.6A TC
Frequency (MHz) 4 31.25 62.5 100 300 500 600
IL Attenuation (dB/100M) 3.5 10.1 14.4 18.2 28 35.4 41.4
Near End Crosstalk Attenuation (NEXT, dB) 100.1 88.7 83 80.1 70.4 59.6 58.6
NEXT Power and PS NEXT (dB) 90.4 87.1 80.4 78.6 68.9 57.8 56.2
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) 95.8 91.5 87 84.1 76.4 71.6 72.6
ACR-F Power and PS ACR-F (dB) 91.4 88.1 85.4 86.3 76.9 69.1 67.9
Return Loss (RL, dB) 40.9 41.3 37.9 35 30.7 22.7 19.7


Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.

Physical Specifications
Conductor Size (nominal value)
4×2×0.57 (AWG23)
Outer Diameter of Cable (nominal
value)
7.3mm
Weight (305m, with package,
nominal value)
18kg

Electrical Properties
DC resistance (20℃ )
93.8Ω/km
Earth Capacity ≦ 5.6 nF/100m (@1kHz)
100MHz Characteristic Impedance
100Ω±15Ω

Mechanical Properties
Minimum Bend Radius (dynamic)
29mm
Minimum Bend Radius (static)
58mm
Maximum Installation Tension
100N
Anti-Extrusion Capacity 1000N/10cm

Flammability (LSZH)
Flame Resistance (of single wire) GB/T 18380.12 (IEC 60332-1-2)
Flame Resistance (of bunched wires) GB/T 18380.35 (IEC 60332-3-24)
Smoke Density GB/T 17651 (IEC 61034-1/-2)
Hazardous Halogen Gas GB/T 17650.1/.2 (IEC 60754-1/-2)

Product Tags:

Ethernet CAT 6A Cable

      

Solid Bare Copper CAT 6A Cable

      

PVC Jacket Ethernet Cable 23AWG

      